Vnitr Lek 1997, 43(5):340-344

[The role of the atrium and optimal values of AV intervals in sequentially paced patients].

J Kvasnicka, M Měs»an, M Tauchman, Z Tusl, V Rozsíval, J Jandík, I Gajdosová
I. interní klinika FN, Hradec Králové.

In 1995, 2249 dual chamber pacemakers were implanted in the Czech Republic. These pacemakers make it possible to set an optimal AV delay between the atrial and ventricular impulse. Although the optimization of the AV interval has its well defined physiologic advantages, it does not seem to be necessary in otherwise healthy individuals with a good atrial and ventricular function. In these patients the default value, usually about 170 ms, is acceptable. However, AV interval optimization--i.e. finding the interval at which the atrial contribution to ventricular filling is maximal--should be done in all patients with left ventricular dysfunction, indicated for pacing because of bradyarrhthmia. In this subset of patients, even a small improvement in ventricular filling is believed to be clinically useful. Moreover, it has been documented, that in some types of ventricular dysfunction the so-called "primary optimization" (i.e. optimization of the AV interval in patients, in whom the pacemaker is not indicated for bradyarrhthmia but for ventricular dysfunction that might be improved by AV interval optimization) may be clinically useful. It is the case in patients with hypertrophic obstructive cardiomyopathy, dilated cardiomyopathy with presystolic regurgitation and AV interval prolongation, and perhaps even in some patients with impairment of ventricular systolic function and substantial prolongation of the AV interval. Despite all that, optimization of the AV interval is not routinely performed because even the best available optimization procedures (stroke volume measurements at different AV intervals by aortic Doppler echography) is observer dependent, time-consuming and costly.

Keywords: Arrhythmias, Cardiac /complications/; Atrial Function; Cardiac Pacing, Artificial /methods/; Heart Conduction System /physiopathology/; Humans; Pacemaker, Artificial; Ventricular Dysfunction, Left /complications/

Published: May 1, 1997  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Kvasnicka J, Měs»an M, Tauchman M, Tusl Z, Rozsíval V, Jandík J, Gajdosová I. [The role of the atrium and optimal values of AV intervals in sequentially paced patients]. Vnitr Lek. 1997;43(5):340-344.
Download citation




Vnitřní lékařství

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.