[Recurrent spontaneous dislocation of the catheter in a venous vascular access port system].

P Zák, V Maisnar, A Lojík, M Tauchman
Odd. klinické hematologie FN, Hradec Králové.

The authors describe the problem of spontaneous changes of the position of the catheter in venous vascuports with a cannula inserted via the vena subclavia or internal jugular vein into the vena cava superior, used most frequently for repeated administration of chemotherapy. The correct position of the catheter is important in the venous port system for the proper function of the whole system. During dislocation of the catheter the function is impaired to a varying extent and the number of inflammatory and thrombotic complications increases and dislocations beyond the venous system lead to extravasal administration of the drug. Possible diagnosis of this condition and subsequent correction of the position of the cannula is described in a 48-year old man who developed spontaneous dislocation of the position of the cannula from the vena cava superior into the internal jugular vein. Correction by means of a hook inserted via the ipsilateral femoral vein into the vena cava inferior and via the vena cava superior into the internal jugular vein was successful only temporarily. Because of repeated dislocation the port system was removed.

Keywords: Catheterization, Central Venous /adverse effects/; Catheters, Indwelling /adverse effects/; Equipment Failure; Humans; Infusion Pumps, Implantable /adverse effects/; Jugular Veins; Male; Middle Aged; Recurrence; Vena Cava, Superior

Published: January 1, 1998  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Zák P, Maisnar V, Lojík A, Tauchman M. [Recurrent spontaneous dislocation of the catheter in a venous vascular access port system]. Vnitr Lek. 1998;44(1):27-29.
Download citation




Vnitřní lékařství

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.