Vnitr Lek 2002, 48(Supplement 1):183-187

[Lead systems in orthogonal electrocardiography].

J Holcík, J Musil
Ustav biomedicínského inzenýrství Fakulty elektrotechniky a komunikacních technologií VUT v Brnĕ.

The paper deals with evaluating quality of some orthogonal and pseudoorthogonal electrocardiographic lead systems as Frank lead system, signals derived from standard electrocardiographic leads by Levkov's transform and some signals of the standard 12 lead system that roughly fulfill condition of geometrical orthogonality. The signals of the lead systems were assessed by means of a mathematical criterion of two vector orthogonality which was originally proposed for purposes of electrocardiography and proved by Netusil. Experiments done with signals of the CSE database of short-time rest ECG records have revealed that the best ECG lead orthogonality has been found for signal sets of I-aVF-V2, and I-III-V2 leads, resp. Unfortunately nearly the worst results were obtained for the widely used Frank orthogonal lead system. It means that this lead system can lead (under some specific conditions) to missing diagnostically important information.

Keywords: Electrocardiography, instrumentation, ; Humans; Vectorcardiography

Published: December 1, 2001  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Holcík J, Musil J. [Lead systems in orthogonal electrocardiography]. Vnitr Lek. 2002;48(Supplement 1):183-187.
Download citation




Vnitřní lékařství

Madam, Sir,
please be aware that the website on which you intend to enter, not the general public because it contains technical information about medicines, including advertisements relating to medicinal products. This information and communication professionals are solely under §2 of the Act n.40/1995 Coll. Is active persons authorized to prescribe or supply (hereinafter expert).
Take note that if you are not an expert, you run the risk of danger to their health or the health of other persons, if you the obtained information improperly understood or interpreted, and especially advertising which may be part of this site, or whether you used it for self-diagnosis or medical treatment, whether in relation to each other in person or in relation to others.

I declare:

  1. that I have met the above instruction
  2. I'm an expert within the meaning of the Act n.40/1995 Coll. the regulation of advertising, as amended, and I am aware of the risks that would be a person other than the expert input to these sites exhibited


No

Yes

If your statement is not true, please be aware
that brings the risk of danger to their health or the health of others.