Vnitr Lek 2008, 54(10):953-960
Immediate and long-term results of conventionally performed radiofrequency catheter ablations of paroxysmal atrial fibrillation
- Interní kardiologická klinika Lékařské fakulty MU a FN Brno, pracoviště Bohunice, přednosta prof. MUDr. Jindřich Špinar, CSc., FESC
Introduction:
Atrial fibrillation is the most frequent cardiac arrhythmia. Epidemiological studies show sharp increase of incidence and prevalence of atrial fibrillation all over the world. Atrial fibrillation is becoming to be a serious problem, not only clinical, but even social and economical. Aim of the paper was to evaluate immediate and long-term results of radiofrequency catheter ablation of paroxysmal atrial fibrillation at Dpt. of Internal Medicine - Cardiology, University Hospital Brno.
Methods:
The patients were indicated for ablation, when the anti-arrhythmic therapy was ineffective. End-point of the ablation was disconnection of myocardial sleeves between left atrium and pulmonary veins and complete electrical isolation of pulmonary veins.
Group of the patients, results:
There were 67 catheter ablations of paroxysmal atrial fibrillation performed within the years 9/2004 to 12/2006 at our department, out of the whole amount of 1,285 ablations of supraventricular tachyarrhythmias from 1995 to 2006. There were 27 women (40%) and 40 men (60%) in our group of patients, with the mean age 56.9 ± 9.5 years. The average ejection fraction of left ventricle was 62 ± 5%, left atrial dimension 42.8 ± 6 mm. The mean follow-up period was 16.9 ± 10.9 months. The patients were treated before and after the ablation by 1 anti-arrhythmic drug in 44.8 vs 50%, by 2 drugs in 40.3 vs 14.9% and by 3 drugs in 10.4 vs 9%, respectively. The percentage of patients without any anti-arrhythmic drug increased after successful ablation from 2.9 to 25.4%, the percentage of patients using amiodarone decreased from 29.8 to 16.4%, propafenon from 29.8 to 16.4% and sotalol from 26.8 to 10.4% respectively. The median of RF application duration was 43.8 min, fluoroscopy time 43.8 min and procedure duration 240 min. The success rates were 87.5% in year 2004, 77.4% in 2005 and 79.2% in 2006.
Conclusion:
Catheter ablation of paroxysmal atrial fibrillation has become a routine curative method in symptomatic patients without major structural heart disease, with ineffective anti-arrhythmic treatment. Ablation was associated with significant reduction of anti-arrhythmic and anticoagulation therapy.
Keywords: atrial fibrillation; paroxysmal atrial fibrillation; radiofrequency catheter ablation; electrical isolation of pulmonary veins
Received: April 22, 2008; Accepted: May 24, 2008; Published: October 1, 2008 Show citation
References
- Cappato R, Calkins H, Chen SA et al. Worldwide survey on the methods, efficacy and safety of catheter ablation for human atrial fibrillation. Circulation 2005; 111: 1100-1105.
Go to original source...
Go to PubMed...
- Fiala M, Chovančík J, Heinz P et al. Léčba symptomatické intermitentní fibrilace síní katetrovou ablací v levé srdeční síni: bezprostřední a dlouhodobé výsledky u 150 pacientů. Vnitř Lék 2005; 51: 971-983.
- Fiala M, Chovančík J, Moravec R et al. Recidivující arytmie po katetrové ablaci původně paroxysmální fibrilace síní a výsledky opakované ablace. Vnitř Lék 2007; 53: 1248-1254.
Go to PubMed...
- Fiala M, Chovančík J, Nevřalová R et al. Pulmonary vein isolation using segmental versus electroanatomical circumferential ablation for paroxysmal atrial fibrillation: over 3-year results of a prospective randomized study. J Interv Card Electrophysiol 2008; přijato k publikaci.
Go to original source...
Go to PubMed...
- Fuster V, Ryden LE, Cannom DS et al. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation: executive summary. Circulation 2006; 114: 700-752.
Go to original source...
Go to PubMed...
- Gammage MD, Parle JV, Holder RL et al. Association between serum free thyrosine concentration and atrial fibrillation. Arch Intern Med 2007; 167: 928-934.
Go to original source...
Go to PubMed...
- Gersh BJ, Tsang TSM, Seward JB. The changing epidemiology and natural history of nonvalvular atrial fibrillation: clinical implications. Trans Am Clin Climatol Assoc 2004; 114: 149-160.
- Haissaguerre M, Jais P, Shah DC et al. Right and left atrial radiofrequency catheter therapy of paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 1996; 7: 1132-1144.
Go to original source...
Go to PubMed...
- Haissaguerre M, Shah DC, Jais P et al. Electrophysiological break-throughs from the left atrium to the pulmonary veins. Circulation 2000; 101: 1409-1417.
Go to original source...
Go to PubMed...
- Kumaraswamy H, Plumb VJ, Epstein AE et al. Resumption of electrical conduction in previously isolated pulmonary veins: rationale for a different strategy. Circulation 2004, 111: 546-554.
- Lábrová R. Epidemilogie fibrilace síní. KF 2007; 5: 6-10.
- Lábrová R. Léčba fibrilace síní v době katetrové ablace. Vnitř Lék 2007; 53: 923-924.
Go to PubMed...
- Marrouche NF, Dresing T, Cole C et al. Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation. J Am Coll Cardiol 2002; 40: 464-474.
Go to original source...
Go to PubMed...
- Matsumoto N, Ryoji K, Kasugai H et al. Experimental study on the effectiveness and safety of radiofrequency catheter ablation with the cooled ablation system. Circ J 2003; 67: 154-158.
Go to original source...
Go to PubMed...
- McGovern PG, Jacobs DR Jr, Shahar E et al. Trends in acute coronary heart disease mortality, morbidity, and medical care from 1985 through 1997: the Minnesota Heart Survey. Circulation 2001; 104: 19-24.
Go to original source...
Go to PubMed...
- Oral H, Scharf C, Chugh A et al. Catheter ablation for paroxysmal atrial fibrillation: segmental pulmonary vein ostial ablation versus left atrial ablation. Circulation 2003; 108: 2355-2360.
Go to original source...
Go to PubMed...
- Pedersen OD, Kober L, Torp-Pedersen C. Atrial fibrillation and atrial cardiomyopathy: two sides of the same coin? Am Heart J 2004; 147: 953-955.
Go to original source...
Go to PubMed...
- Pürerfellner H, Cihal R, Aichinger J et al. Pulmonary vein stenosis by ostial irrigated-tip ablation: Incidence, time course, and prediction. J Cardiovasc Electrophysiol 2003; 14: 158-164.
Go to original source...
Go to PubMed...
- Redfield MM, Jacobsen SJ, Burnett JC Jr et al. Burden of systolic and diastolic ventricular dysfunction in the community: appreciating the scope of the heart failure epidemic. JAMA 2003; 289: 194-202.
Go to original source...
Go to PubMed...
- Risk factors for stroke and efficacy of antithrombotic therapy in atrial fibrillation. Analysis of pooled data from five randomized, controlled trials. Arch Intern Med 1994; 154: 1449-1457.
- Stewart S, Murphy N, Walker A et al. Cost of an emerging epidemic: an economic analysis of atrial fibrillation in the UK. Heart 2004; 90: 286-292.
Go to original source...
Go to PubMed...
- Špinar J, Vítovec J. Losartan - víc než pokles krevního tlaku. Kardiol Rev 2006; 8: 115-120.
- Tsang TS, Gersh BJ, Appleton CP. Left ventricular diastolic dysfunction as a predictor of the first diagnosed nonvalvular atrial fibrillation in 840 elderly men and women. J Am Coll Cardiol 2002; 40: 1636-1644.
Go to original source...
Go to PubMed...
- Tsang TS, Petty GW, Barnes ME et al. The prevalence of atrial fibrillation in incident stroke cases and matched population controls in Rochester, Minnesota: changes over three decades. J Am Coll Cardiol 2003; 42: 93-100.
Go to original source...
Go to PubMed...
- Verma A, Wazni OM, Marrouche NF et al. Pre-existing left atrial scaring in patients undergoing pulmonary vein antrum isolation. An independent predictor of procedural failure. J Am Coll Cardiol 2005; 45: 285-292.
Go to original source...
Go to PubMed...
- Wang TJ, Larson MG, Levy D et al. Temporal relations of atrial fibrillation and congestive heart failure and their joint influence on mortality: the Framingham Heart Study. Circulation 2003; 107: 2920-2925.
Go to original source...
Go to PubMed...
- Watanabe I, Masaki R, Min N et al. Cooled tip ablation results in increased radiofrequency power delivery and lesion size in the canine heart. Importance of catheter-tip temperature monitoring for prevention of popping and impedance rise. J Int Cardiac Electrophysiol 2002; 6: 9-16.
Go to original source...
Go to PubMed...
- Wolf PA, Abbott RD, Kannel WB. Atrial fibrillation as an independent risk factor for stroke: the Framingham Study. Stroke 1991; 22: 983-988.
Go to original source...
Go to PubMed...
- Wolf PA, Benjamin EJ, Belanger AJ et al. Secular trends in the prevalence of atrial fibrillation: the Framingham Study. Am Heart J 1996; 131: 790-795.
Go to original source...
Go to PubMed...